Acoustic Wall and Cladding
Acoustic Wall Construction
A grid system is constructed on the wall using 40×40×2 mm and 20×40×1.5 mm box profiles, in accordance with the project requirements. High-density insulation is applied between the grids to prevent high levels of sound generated within the hall from escaping, and to block unwanted external noise from entering. The acoustic wall construction is completed with the installation of acoustic panels, the model and color of which are selected by the client.
Acoustic Ceiling Construction
A main carrier grid is installed on the ceiling using 40×60×2 mm and 40×40×2 mm box profiles, tailored to the project specifications. High-density insulation is then applied over the grid to contain internal noise and block external sounds from entering the hall. The acoustic ceiling construction is finalized with the installation of acoustic panels, with model and color chosen by the client.